Description
- Built in Boulder, Colorado, USA
- 1200 VA output
- 3X lower impedance than P5
- 4 AU outlets
- 10 amp AC input AU
- 230 volt Regulated AU
- Range 200 –285VAC AU
- 100% regenerated AC
- 4 outlets
- MultiWave
- Pure Sine Wave
- Integrated oscilloscope
- THD meter
- Improvement meter
- Power meter
- Control over the web
- Adjustable output voltage
- Color touchscreen
- Field upgradable
Environment:
Location: Indoor Use Only
Duty Cycle: Suitable for continuous operation
Moisture Sensitivity: No sealed against moisture
Operating Humidity: <80% rh
Storage Temperature: -40 C to +40 C
Operating Temperature: 0 C to 40 C
Max Operating Altitude: 3500 m (12000 ft)
Electrical Supply Nominal Rating: 230 V 10 A 50/60 Hz
Instrument:
Unit Dimensions: 43 x 36 x 10.16 cm (WxDxH)
Unit Weight: 16.7 kg
Shipping Dimensions: 61 x 53 x 25 cm (WxDxH)
Shipping Weight: 21.7 kg
Nominal Input Voltage: 200 – 285 V AC
Maximum Continuous Load: 1500 VA
Maximum Peak Load: 3800 VA
Voltage Regulation: 1 V
Output Distortion (Resistive Load): < 0.9>#br###Output Distortion (Reactive Load): < 0.9%; 0.1% typical
Output Impedance: < 0.008 Ohm
Noise Reduction: 100 kHz – 2 MHz >80 dB
Efficiency: > 85% (at 1200 VA)
Input Frequency: 45 – 65 Hz
Under Voltage: Continuous – 10% of setting 15 sec duration – 15% of setting
Over Voltage: Continuous – 5% of setting 15 sec duration 10% of setting
Energy Dissipation: 1270 J
Peak Current Surge: 90000 A
Max Surge Voltage: 6000 V
Clamp Level: 800 V
DC Trigger Configuration: Tip Positive
DC Trigger Voltage: 5 – 15 V DC
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.